Electroce 220037 PowerMax1650 / PowerMax1250 Plasma consumables
We can offer you all plasma consumables for , Kjellberg, Esab,
Koike, Komatsu, Thermadyne, such as: electrode, nozzle, shield,
swirl ring, inner cap, retaining cap, water tube, torch body and so
on.
Each of our products has been tested with a rigorous precision
instrument, A large number of piercings tests and service life
tests, And made batch trial in our customers. If all results are
good, then we will producing them.
Machine | HEC NO. | Ref NO. | Description |
PowerMAX45 PowerMAX1250 PowerMAX 1650
| H71925 | 120925 | Swirl Ring 40/60/80Amp |
H71051 | 220051 | Swirl Ring 100Amp |
H01926 | 120926 | Electrode 40/60/80Amp |
H01037 | 220037 | Electrode 100Amp |
H11932 | 120932 | Nozzle 40Amp |
H11931 | 120931 | Nozzle 60Amp |
H11927 | 120927 | Nozzle 80Amp |
H11011 | 220011 | Nozzle 100Amp |
H11006 | 220006 | Nozzle 40Amp Without Cap |
H11007 | 220007 | Nozzle 60Amp Without Cap |
H11980 | 120980 | Nozzle 80Amp Without Cap |
H11064 | 220064 | Nozzle 100Amp Without Cap |
H11329 | 220329 | Nozzle 40Amp Fine Cut |
H41928 | 120928 | Retaining Cap 40/60/80Amp |
H41048 | 220048 | Retaining Cap 100Amp |
H41061 | 220061 | Retaining Cap 40/60/80Amp |
H41206 | 220206 | Retaining Cap 100Amp |
H21930 | 120930 | Shield 40/60/80Amp |
H21047 | 220047 | Shield 100Amp |
H21979 | 120979 | Shieldg 40/60/80/100Amp |
H21325 | 220325 | Shieldg 40Amp Fine Cut |
H31404 | 220404 | Shieldg 40Amp Fine Cut |
H81767 | 128767 | T100Torch Body |
H82768 | 128768 | T100 Torch Head |
H91755 | 128755 | T100 Torch Lead |
H91752 | 128752 | T100 Torch Lead |
H81754 | 128754 | Torch Main Body |
H91643 | 128643 | Mounting Sleeve |
H91710 | 128710 | Positioning Sleeve |
H91753 | 128753 | Torch Lead |
H91751 | 128751 | Torch Lead |
H91759 | 128759 | Torch Lead |
H91519 | 058519 | Torch O-ring |
Technical Support:
plasma cutting arc fault analysis
1. air pressure is too low
Plasma cutting machine work, such as work pressure far below
specifications required pressure, which means that the plasma arc
jet velocity weakening, input the air flow is less than the
specified value, this form of high energy and high speed of plasma
arc, causing the incision quality is poor, cut through, incision
tumor of the product phenomenon. The reasons for the lack of air
pressure: air compressor input is insufficient, the pressure of the
cutting machine air regulator is too low, there are oil pollution
in the solenoid valve, the gas path is not smooth, etc.. The
solution is to use before the observation of air compressor output
pressure display, such as does not meet the requirements, can
adjust the pressure or maintenance of air compressor. If the input
pressure has reached the requirements, should check air filter
relief pressure valve regulation is correct; gauge display can meet
the cutting requirements. Otherwise deal with air filter pressure
relief valve to carry out routine maintenance, to ensure that the
input air dry, no oil. If you enter the air quality is poor, will
cause the oil pollution in the valve, the valve is difficult to
open, the valve port can not be fully opened. In addition, torch
nozzle pressure is too low, the replacement valve; gas road section
variable is caused by pressure is too low, according to the
specifications for tracheal replacement.